By Dave Chapman, President
A practical guide for small and mid-sized defense manufacturers, from One Up Solutions Northwest.
Status as of October 2026: CMMC Phase II third-party certification requirements are suspended pending a Department of War review. Phase I self-assessment requirements remain in effect. We’ll update this checklist as the program changes.
If your shop builds parts for the Department of Defense, CMMC 2.0 Level 2 still matters, even with the rollout on hold. In July 2026, the Department of War suspended Phase II of CMMC, the step that would have made third-party (C3PAO) certification a contract requirement starting November 10, 2026. That date is paused while a reform task force reviews the program.
What didn’t change: Phase I self-assessments remain in force, and the safeguarding requirements behind CMMC Level 2, the 110 controls in NIST SP 800-171, still apply to contracts involving Controlled Unclassified Information. The suspension changed how compliance gets verified, not whether you have to protect the data. And when verification requirements return in whatever form, the shops that are already ready won’t be scrambling.
Here's the catch for manufacturers: you aren't securing a tidy office network. You're securing a front office, an engineering bay full of CAD workstations, and a shop floor running CNC mills, PLCs, and machines on operating systems nobody has patched since they were installed. That mix of IT and operational technology (OT) is where most manufacturers get stuck.
We built this checklist around that reality. Work through it phase by phase, check off what you already have, and you'll know exactly where your gaps are before an assessor finds them for you...and you’ll know exactly where your gaps are before a customer, an assessor, or an incident finds them for you.
Phase 1: Know where your CUI lives
You can't protect what you haven't mapped. Before you buy a single tool, figure out exactly where Controlled Unclassified Information (CUI) and Federal Contract Information (FCI) enter your business, where they travel, and where they end up. A tight scope is also the cheapest way to pass: the smaller the footprint that touches CUI, the fewer systems you have to lock down.
- Trace the CUI lifecycle. Follow every drawing and spec from the moment it arrives (PIEE, a procurement portal, or an email from your prime), through engineering (CAD/CAM), onto the floor as G-code, and out through shipping. Write down every stop.
- Segment the shop floor. Older CNC mills, plasma cutters, and PLCs often can't run modern security software. Put them on their own VLANs with strict firewall rules so they can't talk to the corporate network or the internet unless they absolutely need to.
- Inventory every connected device. That means everything: inspection equipment, IoT sensors, label printers, rugged tablets, the old PC bolted to the side of a machine. If it's on the network, it's on the list.
- List your outside providers. Document every IT vendor, cloud service (ERP, file sharing, email), and outsourced engineering partner that touches your data. Any cloud service holding CUI needs to be FedRAMP Moderate authorized or meet the equivalent standard.
Phase 2: Lock down the technical controls (IT and OT)
CMMC Level 2 maps directly to the 110 controls in NIST SP 800-171. These are the ones that trip up manufacturers most often.
Access control and identity
- Kill the shared logins. That generic "ShopFloor" account on the workstation by the mills? It has to go. Every operator, machinist, and supervisor needs their own login, whether that's an Active Directory account, a PIN, or a badge tap, so every action traces back to a person.
- Turn on multi-factor authentication (MFA). Require MFA for remote access and for any privileged account, and for network access to systems that hold CUI. Phones are often banned or impractical on the floor, so hardware keys (like YubiKeys) or badge-plus-PIN setups usually work better.
- Secure your wireless. Put production equipment on its own SSID using WPA3-Enterprise (or WPA2-Enterprise at minimum). Keep guest Wi-Fi completely separate from anything that touches CUI.
Devices and data
- Control USB drives. Machinists move G-code to CNC machines on thumb drives every day. Block USB ports on networked machines. For standalone machines that need USB, set up a scanning station and make it policy that every drive gets scanned before it hits the floor.
- Encrypt CUI at rest and in transit. Engineering workstations, file servers, laptops and backups all need encryption using FIPS-validated cryptographic modules. Any email or file transfer carrying drawings or specs gets encrypted too.
- Set automatic screen locks. Shop-floor terminals should lock after a short idle period (5 to 10 minutes is common) so nobody can walk up and read a drawing while the operator is on break.
Phase 3: Secure the building, not just the network
On a manufacturing floor, physical security matters as much as digital. If an unescorted visitor can glance at a CAD screen or pick up a printed drawing, you're out of compliance.
- Draw a physical CUI boundary. Define the areas where CUI is handled and control who gets in, using badges, keycards, or biometric locks.
- Log and escort visitors. Keep a visitor log (paper or digital) with name, company, purpose of visit, and time in and out. If you also handle ITAR work, capture citizenship as well. Escort visitors any time they're near production lines or engineering.
- Protect paper. Blueprints, routing sheets and travelers that contain CUI get the same care as digital files. Lock them up when they're not in use and cross-cut shred them when the job's done.
- Watch the docks. Make sure shipping labels, manifests and packing slips don't reveal sensitive program details or part specifications to drivers and third-party logistics crews.
Phase 4: Watch the network and plan for a bad day
Compliance isn't a one-and-done project. You need to see what's happening on your network and know exactly what to do when something goes wrong.
- Centralize your logs. Collect logs automatically from firewalls, servers, switches and shop-floor terminals into one place (a SIEM), store them securely, and actually review them for failed logins and unusual traffic.
- Patch on a schedule. Set a regular patching cadence for laptops, engineering workstations and servers. For floor equipment that can't be patched, document compensating controls, like full network isolation, so the assessor can see the risk is handled.
- Build and test your incident response plan. Write a playbook for a cyber incident. Under DFARS 252.204-7012, you have 72 hours from discovery to report a CUI incident through the DoD's DIBNet portal, so the plan has to make that clock realistic. Run a tabletop exercise with leadership and IT at least once a year.
Phase 5: Get your paperwork assessment-ready
When the C3PAO shows up, they assess you on what you can prove. If it isn't documented, as far as they're concerned it doesn't exist.
- Write your System Security Plan (SSP). This is the most important document you'll produce. It explains how your company meets each of the 110 Level 2 controls, covering your corporate network, cloud services, and shop-floor OT.
- Keep a Plan of Action and Milestones (POA&M). If your internal review turns up gaps (say, MFA tokens are still rolling out to operators), document what you'll fix and by when. Be aware the rules are tight: only certain lower-risk controls can sit on a POA&M, you need a minimum score to qualify for conditional certification, and every open item must be closed within 180 days.
- Train every employee. Everyone from the front office to the shipping dock needs cyber awareness training: spotting phishing, handling drawings, following USB rules. Make it about your floor and your processes, not a generic office video.
- Keep a Plan of Action and Milestones (POA&M). If your internal review turns up gaps (say, MFA tokens are still rolling out to operators), document what you’ll fix, who owns it, and by when. The rules for conditional status are tight: Level 1 allows no POA&M at all, and conditional Level 2 status requires a minimum score of 88 out of 110, allows only certain lower-risk controls to remain open, and requires every open item to be closed within 180 days. Treat the POA&M as a work plan, not a parking lot.
Need a hand securing your shop floor?
Most manufacturers we talk to don’t have a full-time security team. They have a lean ops crew, a production schedule to hit, and cybersecurity obligations that didn’t go away when the deadline did.
That's where we come in. One Up Solutions Northwest co-manages IT for manufacturers, deploys threat monitoring, and isolates OT so your machines keep running while your network gets audit-ready. We work alongside your team, not around it.
Book a CMMC readiness gap analysis with One Up Solutions Northwest. We'll walk your facility, map where your CUI lives, and hand you a clear list of what to fix first.