Technician reviewing a tablet beside a cabinet containing network switches and cables

By Dave Chapman, President

Industrial IoT security is difficult because production equipment can outlast its security support, updates may interrupt manufacturing, and many devices cannot run ordinary endpoint protection. Default passwords, older communication protocols, shared interfaces, and uncertain component sourcing add further exposure. The response needs to protect the connections around the equipment as well as account for the limits of the equipment itself.

Equipment Can Outlast Its Security Support

A machine can remain useful long after the systems inside it stop receiving updates. This mismatch between equipment life and security support leaves the team maintaining useful machinery with fewer security options.

Record the device model, the software or firmware it runs, and the support available from its supplier. Include any restrictions on installing additional software. A machine's age alone does not tell the team which safeguards are possible.

That record supports a decision about the connections around the device and the work that needs to be planned. It is more useful than treating every old machine as either safe to keep forever or an immediate replacement project.

Updates Have to Fit Production

Factory-floor maintenance differs from office patching. An update affecting a controller or operator interface needs attention to production availability and the equipment's operating requirements.

Discuss the change with the people responsible for the machinery. Establish the planned maintenance window and the conditions for putting the equipment to service. Keep the reason for a deferred update visible so it does not disappear from the work list.

Network restrictions and monitoring may reduce exposure while a longer-term change is being planned. They should not turn an unresolved limitation into an unsupported claim that the equipment has been fully repaired.

Default Access Can Remain in Place for Years

A factory password is easy to overlook after commissioning. Shared terminals and supplier maintenance arrangements can also make it difficult to see who has access and why.

Set unique credentials at commissioning and keep them in controlled storage. Extend that review to the accounts used for ongoing support. Ask who approves access, who can retrieve credentials, and who removes access that is no longer needed.

NIST guidance on multi-factor authentication explains the need for more than one distinct factor type. A badge, PIN, or biometric by itself is not automatically multi-factor authentication. The method should suit the interface and be checked with the equipment supplier before deployment.

Useful Connections Need Clear Limits

Production equipment may need to communicate with supervisory systems, reporting applications, or an approved cloud service. That need does not justify unrestricted access to the business network.

Separate production, office, and guest traffic and document the communications that must cross those boundaries. Include the business reason for each exception and obtain agreement from operations and IT.

A network segment is only part of that work. The team also needs to review the rules controlling traffic between segments and the activity that will be monitored afterward.

Hardware Sourcing Belongs in the Review

Security work is not limited to software. Counterfeit or poorly documented replacement components deserve attention too.

Ask for supplier traceability, certificates of conformance where appropriate, and records of the parts received. Give technical staff a way to question a substituted component before it becomes part of production equipment.

Those records support purchasing decisions. For parts with uncertain origins, ask the supplier to resolve the discrepancy before installation. Specialist testing may be appropriate for critical components.

Turn the Risks Into Specific Questions

Challenge

Question to answer

First item to review

Ended security support

What updates and assistance remain available?

Supplier support records

Difficult patching

What production interruption and checks are needed?

Maintenance plan

Default credentials

Who changed the original access settings?

Commissioning records

Broad network access

Which connections are actually required?

Traffic rules and approved destinations

Limited device protection

What can be monitored without adding software?

Monitoring coverage

Uncertain components

Can we trace the part to its supplier?

Purchasing and receipt records

Assign an owner to each unanswered question. The useful result is a work list tied to real equipment rather than a collection of general warnings.

Monitoring Needs Follow-Through

Watch network behavior for unexpected destinations, unusual traffic volumes, and protocols outside the expected pattern. That approach can suit equipment that cannot host a modern security agent.

An alert still needs review. Agree on who receives it, who understands the affected equipment, and how operations will be involved in deciding what to do. Avoid treating visibility as the same thing as a completed response.

For a practical sequence of improvements, read Affordable IoT Device Security for the Manufacturing Floor.

One Up Solutions Northwest's Perspective

I would not start by assuming that every older machine needs replacement. I would first check how it connects, who can reach it, and what support its manufacturer still provides.

That review gives us a practical order for the work. Unnecessary connections and unchanged access settings deserve attention alongside longer-term decisions about equipment, monitoring, and maintenance. Production staff need a place in those decisions from the beginning.

"As our company grew, One Up was able to keep pace and provided us with the solutions we needed to stay connected and secure not only in the office environment, but also in the field where we spend most of our time."

- Steve Stewart

FAQs About Industrial IoT Security Challenges

Why can patching be difficult on the factory floor?

Industrial updates may need compatibility checks and a planned interruption. Coordinate security maintenance with changeovers or scheduled equipment work rather than applying an office update routine without review.

Can older devices be monitored without installing software on them?

Their network communications can be monitored instead. That can reveal unexpected destinations, traffic changes, or unusual protocols without adding an agent to the device itself. Coverage still depends on the monitoring arrangement.

Does a separate production network remove every security risk?

No. Necessary connections still need access rules, and devices still need appropriate maintenance and oversight. Segmentation is one part of the security approach, not proof that every device is secure.

Should purchasing staff be involved in IoT security?

Yes. Supplier selection, traceability records, and inspection of received components all deserve review. Purchasing and technical teams need to agree on the documentation required for important replacement parts.

Next Step

Bring a list of connected production equipment and the connections you are unsure about. Schedule an industrial network security assessment with One Up Solutions Northwest to review access, support limits, and practical priorities.

Customer Login

News & Updates

One Up Solutions Northwest is proud to announce the launch of our new website at www.1upnw.com. The goal of the new website is to make it easier for our existing clients to submit and manage support requests, and provide more information about our services for ...

Contact us

Learn more about what One Up Solutions Northwest can do for your business.

One Up Solutions Northwest
8060 SW Pfaffle street Suite 108
Tigard, Oregon 97223